Testing stock firmware
Use stock 1.0.1.77 with profile wp3-stock. Start with the
browser emulator or prepare desktop storage using
First boot. Keep each run’s log and
selected input values. The status page
distinguishes existing results from tests that still need coverage.
Display and controls
Section titled “Display and controls”Open the app list with a short crown press. Scroll in both directions using the crown, then repeat using touch. Open an app and return to the face. Hold the face to open its picker and check the selected face after leaving the picker. For graphics changes, repeat with all seven stock faces.
Simulated sensors
Section titled “Simulated sensors”The browser groups inputs under Simulation. The desktop viewer uses Advanced. Change one input at a time while the corresponding stock screen is measuring; merely changing a host control does not prove that stock read it.
| Input | What to observe |
|---|---|
| Orientation and gyro | Level, tilt or angular values should follow the supplied motion. |
| Ambient light | The light test should respond to a changed lux value. Lux measures illumination. |
| GPS | Start a stock mode using the receiver, then compare the displayed fix with the supplied coordinates. |
| Battery and charger | Set Battery level in the browser and compare it with the stock percentage. Toggle the charger separately and check the charging indicator. |
| Optical samples | Enable raw samples and worn state, then start a stock measurement. |
For optical tests in the browser, enable Simulate optical sensor signals and Watch is worn under Optical sensors. Open Heart rate or Blood oxygen and allow stock to calculate a result. Check the history screen separately. Set measurement results supplies values directly for display tests, which does not test the raw-sample calculation. See optical interfaces for the driver-level behavior.
Passcodes
Section titled “Passcodes”In stock Settings → Passcode, create a disposable numeric code or gesture. Enable off-wrist detection, return to the face with Watch is worn on, then turn it off. Verify that stock locks, rejects an incorrect entry and accepts the correct one. Repeat independently for the other passcode type. Browser reload persistence is a separate test, not part of this unlock check.
Record failures
Section titled “Record failures”Save the watch log before resetting. Include the exact interaction and whether sound or controls still worked after the display failed. Keep desktop and browser results separate. See Troubleshooting for connection, file and startup problems. Tests here run in virtual storage and do not require flashing a watch.